When POSTing a request with a payload, and reusing the same httpclient
lua instance, one could encounter a spinning of the httpclient appctx.
Indeed the sent counter is not reset between 2 POSTs and the condition
for sending the EOM flag is never met.
Must fixed issue #1593.
To be backported in 2.5.
(cherry picked from commit
10a37360c8c5dfc4a65aba81f67ae63fe5fa2161)
[wla: context changes]
Signed-off-by: William Lallemand <wlallemand@haproxy.org>
hlua_hc = hlua_checkhttpclient(L, 1);
+ hlua_hc->sent = 0;
+
hlua_hc->hc->req.url = istdup(ist(url_str));
hlua_hc->hc->req.meth = meth;